Length of Activation for Plasma Treatments
 
The length of time the activation from plasma treatment remains is dependent on the material, system, and specific treatment. It is a common misconception that plasma activation lasts “forever.” However, plasma activation for metals may last only for minutes or hours, and the user needs to plasma activate the metal again to acquire the same results. Plastics have a longer period where they are activated; they may be activated for as long as a couple of months. Activation can be measured by using contact angle measurement or with test inks, and Thierry can determine the best parameters for plasma treatment for its customers.
Plasma Treatments and Types of Plasma Coating
 
Many industries use plasma treatment technology to plasma coat surfaces. Plasma treatment may be used for aerospace or automotive components. Surfaces on a large range of materials can be coated with ultra-thin polymer layers. These layers may increase the performance or the aesthetics of the material. After plasma coating, the surfaces may become hydrophilic or hydrophobic based on the customers’ desired result. There are two types of plasma coating: plasma-enhanced chemical vapor deposition processes (PECVD) and physical vapor deposition (PVD). To form a coating layer on the surface, the following steps have to occur in the plasma treatment system:1. The gas is added in the system2. The gas is ionized to form plasma3. The particles diffuse through the plasma sheath4. Electrons bombard the surface5. The particles adsorb onto the surface
 
A Plasma System to Suit Each Application & Advantages of Plasma-enhanced Chemical Vapor Deposition (PECVD)Adhesion Science & Adhesion TreatmentsAnisotropic Etching & The Methods and Uses for Anisotropic EtchingApplications of a Plasma Asher & Surface ModificationArgon Plasma & Argon Plasma Role in Micro-SandblastingAtmospheric Pressure Plasma & Applications of Atmospheric Pressure PlasmaBonding Polyethylene & Using Plasma for Bonding PolyethyleneCoating PVD & Advantages and Disadvantages of Coating PVDContact Angle Measurements & How to Measure Contact AnglesCorona Discharge & The Properties of Corona DischargesCorona Treatment & The Differences between Corona Treatment and Atmospheric PlasmaCVD & Plasma Enhanced CVDDifferences between the Types of Plasma Treatments, Specifically Plasma Coating & Plasma Treatments IntroductionDry Etching & Dry Etching vs. Wet EtchingDry Etching (Plasma Etching) and Wet Etching & Advantages and Disadvantages of Dry Etching (Plasma Etching) and Wet EtchingDyne Levels & Determining a Dyne Level Using a Dyne TestDyne Testing & More about Dyne TestingEtching Silicon & How Etching Silicon is DoneEvaporated Coatings & Methods of Applying Evaporated CoatingsHF Etching & Buffered HF EtchingHistory of Plasma Treatment & Why Powder Plasma Treatment?How to Measure Surface Tension & More Methods of Measuring Surface TensionHydrogen H2 Plasma & Oxide-Layer Reduction with Hydrogen PlasmaHydrogen Peroxide Plasma & The Advantages and Uses of Hydrogen Peroxide Plasma SterilizationHydrophilic Treatment & How Hydrophilic Treatment WorksHydrophobic Coatings vs. Hydrophilic Coatings & Uses for Hydrophobic CoatingsInductive Plasma & The Application of Inductive PlasmaIndustries That a Plasma Asher is Used In & Plasma Etch Customer Parts (Plastic, Metal, Glass)Intelligent Textiles & The Possible Applications of Intelligent TextilesIsotropic Etching & Wet Isotropic Etching vs. Dry Isotropic EtchingLength of Activation for Plasma Treatments & Plasma Treatments and Types of Plasma CoatingLow Pressure Plasma Systems & Types of Low Pressure Plasma SystemsMaximizing Coating Adhesion & Applications of Improving Coating AdhesionNanotechnology Fabrics & Nanotechnology Fabric ProcessesNitrogen Plasma & Nitrogen Plasma vs. Oxygen PlasmaOleophobic Coating & Oleophobic Coating Plasma TreatmentOxide Etch & Buffered Oxide Etch vs. Plasma EtchOxygen Plasma Etching & How Oxygen Plasma Etching is AccomplishedPECVD Industrial Applications & PECVD EfficiencyPECVD Is an Improved Method of Chemical Vapor Deposition & Operation of PECVD SystemsPhysical Vapor Deposition & Physical Vapor Deposition ApplicationsPlasma Applications & Plasma applications in Surface ModificationPlasma Asher & How is Plasma Ashing Done?Plasma Asher Tailored to the Customer & Plasma Etchers and SelectivityPlasma Beam & Plasma Beam ApplicationsPlasma Bonding & The Techniques for Plasma BondingPlasma Etching Tailored to the Customer & Plasma Etcher ParametersPlasma Frequency & Ranges of Plasma FrequencyPlasma Gas & Plasma Gas (Partially Ionized Gas) – Degree of IonizationPlasma Generator & Types of Plasma GeneratorsPlasma Surface Modification & Plasma Surface SciencePlasma Surface Technology & Surface Technology CapabilitiesPlasma Treatment of Different Materials & Plasma Treatment of Silica PowderPlasma Treatment of Powder Applications & Experienced Powder TreatmentPlasma Treatment of Textiles & Plasma Treatment of Textiles: Medical and Technological ApplicationsPlasma Treatment Services & The Use of Corona and Plasma Treatment to Modify Contact AnglePlasma Treatment Systems & Plasma TreaterPlasma Treatments and the History of Plasma & Plasma Treat Different MaterialsPowder Treatment for the Customer & Industries that Need Powder TreatmentSteps of Dry Etching (Plasma Etching) and Wet Etching & Dyne Levels and Plasma Etching TechnologiesSurface Coating with PECVD System & Applications of PECVD SystemsSurface Treatments & Uses for Surface TreatmentsThierry Plasma Systems & What is Plasma-enhanced chemical vapor deposition (PECVD)?What Industries Plasma Etching Is Used In & Plasma Etching MechanismsWhat is a Plasma Asher? & Differences between Plasma Etch and Plasma AshWhat is Plasma Density? & Plasma Density: Cold and Hot PlasmaWhat is Plasma Treatment? & Plasma Treatment of Powders

Contact form light

Contact Request
*required
**required if you want a callback